Pressure rating(300LB) | Maximum test pressure(psig) | ||
Shell test | 1125 | ||
Back seal test | 815 | ||
Seal test | 815 | ||
Tightness test | 80 | ||
Medium operating temperature (ºF) |
-20~100 ~150 ~200 ~250 ~800 |
Maximum working pressure (psig) |
720 705 675 665 410 |
Part name | Material |
Body,Bonnet,Yoke | WCB |
Wedge | WCB+Cr13 |
Stem | 1Cr13 |
Seat ring | 20#+802 |
Packing | Flexible Graphite |
RTJ flange gasket | 304 SS+ Flexible Graphite |
Stem nut | A439-D2 |
Bolt,Nut | A193-B7,A194-2H |
Nominal Size DN |
Conduit diameter D |
Flow damp factor ξ |
Volume flow qV |
Pressure losing △P |
Flow factor | |
AV | KV | |||||
mm | m | m3/s | Pa | m3/h | m3/h | |
40 | 0.038 | 0.50 | 0.002268 | 1000 | 0.002268 | 81.008 |
50 | 0.050 | 0.50 | 0.003927 | 1000 | 0.003927 | 140.250 |
80 | 0.076 | 0.40 | 0.009073 | 800 | 0.010144 | 362.280 |
100 | 0.100 | 0.20 | 0.015708 | 400 | 0.024836 | 887.017 |
150 | 0.150 | 0.10 | 0.035343 | 200 | 0.079029 | 2822.470 |
200 | 0.201 | 0.08 | 0.063462 | 160 | 0.158654 | 5666.227 |
250 | 0.250 | 0.08 | 0.098175 | 160 | 0.245437 | 8765.605 |
300 | 0.300 | 0.07 | 0.141372 | 140 | 0.377832 | 13493.989 |
The fault will happen probably | The reason of fault | The ways to eliminate |
Packing leakage | 1.Not impact the packing gland 2.The packing number not enough 3.The packing is lapse using too long time or keeping unwell |
1.Screw down the nut equality and impact the packing gland 2.Add the packing number 3.Change the new packing |
Leakage between the seal | 1.The dirt and soil attach the seal 2.Seal damage |
1.Clean up the dirt and soil 2.Machine and repair the seat, wedge seal |
Body and bonnet joint leakage | 1.Bolt joint firm not equality 2.Flange seal damage 3.Gasket rupture or lapse |
1.Screw down the bolts equability 2.Repair the seal again 3.Replace the new gasket |
The twirl of handwheel flexible or the wedge not open and shut | 1.Packing pressured too tight 2.Gland flange and gland device askew 3.Stem nut damage 4.The screw of stem nut flay and rupture badly 5.Stem inflect |
1.Properly unscrew the nut of packing gland 2.Adjust the gland flange and gland 3.Disassemble repair screw and clean up the dirt and soil 4.Replace the stem nut 5.Adjust the stem |